Testo
Testo 320 - Super efficient flue gas analyzer
Model No :
Testo 320
Part Code :
0632 3220

Overview

The testo 320 flue gas analyzer is a best solution for all those people who specialise in installing, inspecting and servicing heating systems. It is easy to use and allows you to carry out all measurements in and around heating systems with only one device.The testo 320 flue analyzer comes with one sensor for O2 and additionally you can order a CO sensor (separate product). The flue gas analyzer calculates the relevant flue gas values, i.e. CO2 value, efficiency and flue gas loss.

Features
-Six applications, one device:- flue gas, flue draft, pressure, gas leak detection, CO ambient air and pressure difference measurements
-Integrated flue gas sensors with temperature sensor included :- ultra-fine pressure sensors and a wide range of other sensors, ports and probes optional
-Rugged, high-quality design, high-resolution, multi-color display, self-explanatory menu guide

Major Applications
- Flue gas measurements
- Flue draft measurements
- Gas flow and static gas pressure
- Gas leak detection
- CO ambient air measurements
- Temperature difference measurements

Technical Specifications
- Differential Pressure piezoresistive measuring range: -200 to 200 hPa; Accuracy ±0.5 hPa (-49.9 to 49.9 hPa)
- Absolute Pressure measuring range: +600 to +1150 hPa ; Accuracy ±10 hPa
- Flue gas O2 measuring range: 0 to 25 Vol.%; Accuracy ±0.2 Vol.%
- Flue gas CO (with H2-compensation) measuring range: 0 to 10000 ppm; Accuracy ±10 ppm or ±10 % of mv (0 to 200 ppm);
- Flue gas COlow measuring range: 0 to 500 ppm; Accuracy ±2 ppm (0 to 39.9 ppm) ±5 % of mv (Remaining Range)
- Flue gas NO2 measuring range: 0 to 500 ppm; Accuracy ±10 ppm (0 to 199 ppm)
- Flue gas SO2 measuring range: 0 to 5000 ppm ; Accuracy ±10 ppm (0 to 99 ppm)
- Differential Pressure flue gas Draught piezoresistive measuring range: -40 to +40 hPa; Accuracy ±0.03 hPa (-2.99 to +2.99 hPa)
- Temperature measuring range: -40 to +1200 °C; Accuracy ±0.5 °C (0 to +99 °C)
- Flue gas degree of effectivity, Eta (calculated) measuring range: 0 to 120 %; Resolution 0.1 %
- Flue gas dewpoint (calculated) measuring range: 0 to 99.9 °Ctd; Resolution 0.1 °Ctd
- Flue gas CO2 calculation (calculated from O2) measuring range: 0 to CO2 max; Accuracy ±0.2 Vol.%

General Specifications
- Operating temperature: -5 to +50 °C
- Protection class: IP40
- Connectable probes: 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure
- Display type: graphic Display
- Display size: 160 x 240 pixels
- Max. neg. press./flue gas: -200 mbar
- Max. pos. press./flue gas: 50 mbar
- Pump flow: 0.6 l/min (regulated)
- Interface: Bluetooth®; USB; IR/IRDA interface; gas outlet; Mains connection; probe input/ probe inputs; Differential Pressure
- Storage temperature: -20 to +50 °C
- TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV