Technical Specifications
- Breaker operation Sequences: C, O, C-O, O-C, O-C-O - Continuous current: 5 AMax current25 A during 300 ms, rest time 1 min - Contact function: Two independent control functions - Contact characteristics: Non bouncing, closing time max. 0.1 ms - Make/Break capacity: 25 A, 250 V (AC or DC) per contact function - Start breaker operation: By rotary switch - Pulse length: Adjustable in steps of 10 ms - Pulse delay: Adjustable in steps of 10 ms - Working voltage: 250 V AC / DC - Measurement time: 1 to 100 s - Resolution: 0.1 to 10 ms - Number of channels: 3 with common ground - Time base inaccuracy: 0.05% of the reading ± resolution - Status thresholds: Closed< 10 ? ±20%, Resistor10 ? ±20% to 3 k? ±20%, Open> 3 k? ±20% - Open circuit voltage: 24 V ±20% - Short circuit current: 100 mA ±20%
|
General Specifications
- Mains voltage: 115 / 230 V AC (switchable), 50 / 60 HzPower consumption100 VA (max) - Dimensions Instrument: 360 x 210 x 190 -mm (14.2” x 8.3” x 7.5”) - Temperature: • Operating: 0°C to +50°C (32°F to +122°F) • Storage & transport: -40°C to +70°C (-40°F to +158°F) - Humidity: 5% – 95% RH, non-condensing - Display: LCD - Available languages: English, German, French, Spanish, Swedish - CE-marking • EMC: 2004/108/EC • LVD: 2006/95/EC
|