Megger
Megger PAT350 Handheld Portable Appliance Tester
Model No :
Megger PAT350
Part Code :
1000-953

Overview

The Megger PAT350 series will carry out all test requirements automatically with one button press. PAT350 has additional flash test functions and is the ideal tester for high throughput requirements if you work in a tool hire company or a service centre.
The PAT350 series provides outstanding productivity with the capability to test record numbers of appliances per hour.
In addition to automatic testing, the ability to run each test individually is particularly well suited to service and repair organisations carrying out fault diagnostics.

Features
- Simple manual or automatic testing
- 230 V and 110 V operation
- Bond testing at 25 A,10 A and 200 mA
- Full colour display
- Tests portable RCDs and extension leads
- Outstanding productivity

Technical Specifications
- Electrical supply range : 230 V ±10% ±1 V @ 50 Hz ±10% ±0.1 Hz
- Bond test : (10 A and 25 A)
- Earth bond resistance accuracy : ±5% ±3 digits (0 to 0.49 O)±5% ±5 digits (0.5 to 1.99 O)
- Earth bond resistance resolution : 10 mO (0 to 1.99 O)
- Display range : 10 to 1.99 O Continuity
- Continuity test voltage : 4.0 V d.c. -0% +10
- Continuity resistance accuracy : ±5% ±3 digits (0 to 0.49 O)±5% ±5 digits (0.5 to 19.99 O)
- Continuity resistance resolution : 10 mO (1 to 19.99 O)
- Display range: 0 to 19.99 O
- Insulation test : (250 V and 500 V)
- Insulation resistance accuracy : (230 V):±2% ±5 digits (0 to 19.99 MO)±5% ±10 digits (20 to 99.99 MO
- Flash test voltage : 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II

General Specifications
- Operating temperature range and humidity : -10 to +50 °C90% RH @ -10 to +30 °C75% RH @ +30 to +50 °C
- Storage temperature range and humidity : - 20 to +60° C90% RH @ -10 to +30 °C75% RH @ +30 to +50 °C
- IP rating: IP40
- Safety : IEC 61010-1: CAT II 300V
- EMC : IEC 61326-1: 2006, IEC 61326-2-2: 2005.