Technical Specifications
- Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel
- Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz, Number of harmonic orders: Max. 100th order
- Maximum analysis frequency: 200 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz
- Voltage range: 15 to 1500 V, 7 ranges
- Current range: 0.1 A to 20 kA (depends on current sensor)
- Power range: 0.0150 W to 39.600 MW
- Frequency band: DC, 0.5 Hz to 200 kHz
|
General Specifications
- Data update rate: 50 ms
- Display refresh rate: 200 ms
- External interfaces: LAN, USB (for communication/ memory), RS-232C (for communication/LR8410 link), CF card, Synchronization control, External Control.
- Auto-Save Functions: Each value is stored to CF card during every measurement interval
- Power supply 100 to 240 V AC, 50/60 Hz, 140 VA max.
- Mass: 4.6Kg
|