Fluke
Fluke 773 Milliamp Process Clamp Loop Meter
Model No :
Fluke 773
Part Code :
3362365

Overview

Fluke 773 Milliamp Process Clamp Meter saves time and money by measuring 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop.The 773 also sources and measures dc voltage, so it can be used to troubleshoot voltage input and output devices. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.

Features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals

Major Applications
- Troubleshooting transmitters, valves, and programmable logic controllers (PLCs) Calibrate and maintain Control
- Instrumentation Field Checking of Loop-powered isolators
- Field Checking of Loop-powered transmitters
- Testing Valve positioners
- Verifying process scaled, indicators

Technical Specifications
- mA measurement (measured by clamp) Resolution / range: 0 to 20.99 mA; Accuracy 0.2% + 5 counts
- Resolution / range: 21.0mA to 100.0 mA
- mA measurement (measured in series with test jacks) Resolution / range: 0 to 24.00 mA; Accuracy 0.2% + 2 counts
- mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range: 0 to 24.00 mA; Accuracy 0.2% + 2 counts
- mA simulate (maximum voltage 50 V dc) Resolution / range: 0 to 24.00 mA
- Voltage source (2 mA maximum drive current) Resolution / range: 0 to 10.00 V DC
- Voltage measure Resolution / range: 0 to 30.00 V DC

General Specifications
- Diameter of measurable conductor: 0.177" or 4.5 mm max
- Operating temperature: -10 to 50ºC
- Storage temperature: -25 to 60ºC
- Operating humidity: < 90% @ <30ºC, < 75% @ 30 to 55ºC
- Operating altitude: 0 to 2000 m
- IP rating: IP 40
- Vibration: Random 2 g, 5 to 500 Hz
- Shock: 1 meter drop test (except the jaw)
- EMI/RFI: Meets EN61326-1