Fluke
Fluke 190-062-S ScopeMeter(R) Test Tool
Model No :
FLUKE-190-062/s
Part Code :
4025248

Overview

the Fluke ScopeMeter 190-062/S combines an unprecedented level of performance, ruggedness, and portability with 60 MHz bandwidth and real-time sampling rates up to 625 MS/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail.
he Fluke ScopeMeter 190-062/S portable scope is double-insulated two-channel floating oscilloscope.

Features
-Two electrically isolated inputs
-CAT III 1000 V / CAT IV 600 V safety rated
60 MHz bandwidth model
625 MS/s
-Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
-Dedicated 5000 Count digital multimeter
-Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
-ScopeRecord roll mode, capture waveform sample data for up to 48 hours
- TrendPlot, trend measurement readings for up to 22 days
- Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)

Major Applications
Filed Electronics troubleshooting.
Technical Specifications
- Bandwidth: 60 MHz
- Number of channels 60 MHz: 2 channels
- Real-time sample rate 625 MS/s
- Inputs 2 scope plus DMM input
- Timebase range 10 ns - 2 min/div
- Input sensitivity 2 mV-100 V/div
- Trigger types Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
- Trigger source: Any scope input channel, or external via DMM input
- Glitch capture 8 ns
- Maximum record length :-ScopeRecord mode: 30,000 pts; Scope mode: 10,000 pts per input

General Specifications
- Operating temperature:
• 0 °C to 40 °C Including Batteries
• 0 °C to 50 °C Excluding Batteries
- Storage temperature: -20 °C to +60 °C
- Safety Specifications: Electrical safety 1,000V CAT III/600V CAT IV (EN61010-1)
- Weight: 2.2 kg
- Li-Ion battery: BP 290 (2400mAh)