Technical Specifications
- AC voltage measurement
- Range : 500 V
- Resolution : 0.1 V
- Accuracy : 45 Hz – 66 Hz, 0.8% + 3
- Continuity testing (RLO)
- Range (autoranging) : 20 O / 200 O / 2000 O
- Resolution : 0.01 O / 0.1 O / 1 O
- Insulation resistance measurement (RISO)
- Test voltages : 50-100-250-500-1000 V
- Accuracy of tTest voltage (at rated test current) : 10%, -0%
- Loop and line impedance (ZI)
- Range : 10 O / 0.001 O / High current mO mode
- RCD testing, RCD types tested
- RCD Type : AC¹ ,G²,S³
- Model 1664 : A, AC, B5, S
- Earth Resistance Test (RE)
- Range : 200 O / 2000 O
- Resolution : 0.1 O / 1O
|
General Specifications
- Battery size, quantity : Type AA, 6 ea.
- Sealing : IP-40
- Safety : Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
- Overvoltage : CAT III / 500V; CAT IV 300V
|