Fluke
Fluke MDA-510 Motor Drive Analyzer
Model No :
Fluke MDA 510
Part Code :
4984691

Overview

The Fluke MDA 510 Motor-Drive Analyzer saves time and eliminates the hassle of setting up complex measurements, while simplifying the troubleshooting process for variable frequency drives. It has a simple process which has a step-by-step guided measurements for showing where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself.

Features
- Guided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than ever
- Preset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configuration
- Built-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports

Major Applications
- Safely locate and troubleshoot typical problems on inverter type motor-drive systems.
Technical Specifications
- Measurement Function- DC voltage (V dc):
• Maximum voltage with 10:1 or 100:1 probe: 1000 V
• Maximum resolution with 10:1 or 100:1 probe: 1 mV
-AC voltage (V ac):
• Maximum voltage with 10:1 or 100:1 probe: 1000 V
• Maximum resolution with 10:1 or 100:1 probe: 1 mV
- True-rms voltage (V ac+dc)-
• Maximum voltage with 10:1 or 100:1 probe: 1000 V
• Maximum resolution with 10:1 or 100:1 probe: 1 mV
- PWM voltage (V pwm)
• Purpose: To measure on pulse width modulated signals, like motor drive inverter outputs
- Peak voltage (V peak):
• Modes Max peak, min peak, or pk-to-pk
• Maximum voltage with 10:1 or 100:1 probe: 1000 V
• Maximum resolution with 10:1 or 100:1 probe: 10 mV

General Specifications
- Current (AMP) with current clamp:
• Ranges: Same as V ac, Vac+dc or V peak
• Scale Factors: 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A
- Frequency (Hz):
• Range: 1.000 Hz to 500 MHz
• Full scale reading: 999 counts
- Voltage/Herz ratio (V/Hz):
• Purpose: To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives
- Voltage unbalance drive input:
• Purpose: To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages
- Voltage unbalance drive output and motor input:
• Purpose: To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages